QSR1
QSR1® introduced the Quantitative Short Range technique to the field of Non‑Destructive Testing (NDT). As the first guided wave scanning instrument, it made possible to measure wall thickness in areas where direct access is not available. Developed around the challenge of quantifying Corrosion Under Pipe Supports (CUPS), QSR1® established a practical means to quantitatively assess the pipe‑to‑support contact area without access to the underside of the pipe, which is required by other methods. The same approach is now applied across the QSR® System, extending beyond pipe supports to a wider range of features.
Description
Specifications
Pipe Diameter
6″ to 24″ (DN 150 to 600) – Nominal API 5L
Pipe Wall Thickness
6 mm to 13 mm (0.236″ to 0.512″)
Operating Temperature
‐20°C to 70°C (‐40°F to 160°F)
Communications
USB, LAN
Clearance
Varies according to diameter:
from 210 mm to 170 mm [8.3″ to 6.7″]
Special frames available for limited clearance.
Pipe Orientation
Horizontal (±15 degrees)
Surface Preparation
Surface must be wiped clean of loose debris.
Coatings thicker than 1 mm must be removed under the sensor.